Description
Model 9363 is a multipurpose, stainless-steel S-type load cell that can be used in tension or compression.
The product is suitable for a wide range of hybrid scales, overhead track scales, belt scales, and process-weighing applications.
Reliable sealing is ensured by the proprietary TRANSEAL potting compound and additional mechanical protection of the strain gage area.
The product meets the stringent Weights and Measures requirements throughout Europe and the USA.
Features
- Capacities: 50 to 10,000 kg (50 to 20,000 lbs)
- Stainless-steel construction
- Suitable for compression and tension applications
- Trimmed output versions standard
- Sealing: IP67
- Certified to OIML R-60, 3000d, NTEP class IIIL, 10000 divisions
Options
- FM approved for use in potentially explosive atmospheres
Description
Model 9363 is a multipurpose, stainless-steel S-type load cell that can be used in tension or compression.
The product is suitable for a wide range of hybrid scales, overhead track scales, belt scales, and process-weighing applications.
Reliable sealing is ensured by the proprietary TRANSEAL potting compound and additional mechanical protection of the strain gage area.
The product meets the stringent Weights and Measures requirements throughout Europe and the USA.
Features
- Capacities: 50 to 10,000 kg (50 to 20,000 lbs)
- Stainless-steel construction
- Suitable for compression and tension applications
- Trimmed output versions standard
- Sealing: IP67
- Certified to OIML R-60, 3000d, NTEP class IIIL, 10000 divisions
Options
- FM approved for use in potentially explosive atmospheres
Parameter |
Value |
Unit |
Rated capacity (kg) |
50, 100, 250, 500, 1000, 2500, 5000, 7500, 10000 |
kg |
Rated capacity (lbs) |
50, 75, 100, 150, 200, 250, 300, 500, 750, 1k, 1.5k, 2k, 3k, 5k, 10k, 15k, 20k |
lbs |
NTEP/oiml accuracy class |
NTEP IIIL |
Non-Approved |
OIML C3 |
|
Max. no. of intervals (n) |
10000 |
D3 |
3000 |
|
Rated output R.O |
3 |
mV/V |
Rated output tolerance |
0.0075 |
±%mV/V |
Zero balance |
1 |
±%FSO |
Non-repeatability |
0.0100 |
0.0100 |
0.0100 |
±%FSO |
Creep error |
— |
±%FSO |
Ultimate over load |
250 |
% of R.C |
Excitation voltage |
5 to 12 |
VDC or VAC RMS |
Max. excitation voltage |
15 |
VDC or VAC RMS |
Input resistance |
390±15 |
Ω |
Output resistance |
350±3.5 |
Ω |
Insulation resistance |
≥5000 |
MΩ |
Environmental protection |
IP67 |
|
- FSO - Full Scale Output
- All specifications subjects to change whithout notice.
Applications
- Suspended hoppers
- Overhead track scales
- Force measurement